Solar Flashing: How Your Roof Stays Dry When Panels Go On

Every lag bolt into your roof is a hole. Good solar flashing is why those holes stay dry through 30 Minnesota winters. Here's what it is, what to look for and what to ask.

★★★★★ 86 Google reviews500+ customers30-yr warrantyLicensed EA761814 · BC810322Family-Owned & OperatedVeteran-OwnedBBB A+ Accredited
Solar racking rails being fastened to roof attachments on a Minnesota home during installation

Reviewed by John Ihle, MN Master Electrician (AM005101) · NABCEP-credentialed · iSolar, Saint Paul Park, MN · Last reviewed October 2026

The short answer: Solar flashing is a metal or composite plate that slides under the shingle course above each roof attachment, so water sheds over the bolt instead of into it. A properly flashed mount relies on the roof's own shingle overlap, with a gasket as a second layer; sealant alone is a backup, not a waterproofing plan. Metal roofs often need no penetration at all.

What solar flashing actually does

A typical rooftop array sits on rails, and those rails sit on attachments that are lagged into your rafters. On a 7–10 kW system that can mean several dozen holes in your roof. Solar flashing is the part that keeps each of those holes dry.

The idea is the same one your roof already uses. Shingles work because each course overlaps the one below it, so water always runs over a seam, never into it. A solar roof flashing is a flat plate, usually aluminum, that slides under the shingle course above the attachment point. Water that runs down the roof hits the upper shingle, flows onto the flashing, and keeps going over the shingle below. The lag bolt comes up through a raised boss or collar on the flashing, and a rubber (EPDM) washer seals the bolt itself.

That gives you layers: the shingle overlap sheds the bulk of the water, the raised collar keeps standing water away from the hole, and the gasket stops what's left. No single layer has to be perfect.

Flashed mounts vs sealant-only mounts

The cheapest way to attach solar is an L-foot lagged straight through the top of the shingle with a bead of sealant under it. It can look fine on install day. The problem is time: sealant is exposed to UV, freeze-thaw cycles and thermal movement every day, and it's the only thing between water and your roof deck.

Attachment typeHow it keeps water outWhat fails firstOur take for Minnesota
Sealant-only L-foot on top of shingleOne bead of sealantSealant cracks or pulls away after freeze-thaw cyclesAvoid on shingle roofs
Flashed mount (plate under the upper course)Shingle overlap + raised collar + gasketUsually nothing, if placed and fastened correctlyOur standard on asphalt shingles
Flashless mount with built-in gasket and sealantCompressed gasket + sealant cavityDepends on product listing and install qualityAcceptable when listed and installed to the manual; ask for the spec sheet
Standing-seam clamp (metal roof)No hole in the roof panelClamp set incorrectly on the seamBest option on standing-seam metal

Sealant still has a role. Manufacturers typically call for filling the pilot hole with a roofing-compatible sealant before the lag goes in. But in a well-designed solar panel roof mount flashing system, sealant is the backup layer. IronRidge, for example, notes that its FlashVue flashing's water-seal ratings were tested without sealant, and it passed the UL 441 rain test and the TAS 100(A) wind-driven rain test per Intertek.

How a flashed shingle mount goes in (the installer's view)

Here's what a correct solar roof flashing install looks like on asphalt shingles, using one common product as the example. Details vary by brand, so the installation manual for the exact part on your roof is the rulebook.

  1. Find the rafter. The lag has to hit the center of a rafter or truss. A lag that misses wood holds nothing and leaves an unsealed hole under the flashing.
  2. Lay out and drill a pilot hole. IronRidge's FlashVue guide calls for a 1/4-inch pilot hole, filled with the roofing manufacturer's approved sealant.
  3. Slide the flashing under the courses. For FlashVue, the plate goes between the first and second courses, with its top at least 3/4 inch above the edge of the third course and its bottom above the edge of the first. That upper overlap is what keeps water on top of the flashing.
  4. Drive the lag through the collar. The guide specifies a 5/16 x 4.25-inch lag with an EPDM-backed washer, tightened until fully seated. Over-driving can crush the gasket; under-driving leaves it loose.
  5. Attach the rail. Only after the attachment is sealed does the racking go on.

On Twin Cities installs, the step crews most often have to work around is a shingle nail sitting right where the flashing needs to slide. A nail that blocks the plate has to be dealt with properly (not just bent down), or the flashing rides up and the overlap shrinks. Ask your installer how they handle it.

Shingle vs metal vs other roofs

Asphalt shingles

Flashed mounts are the standard. Brittle or curled shingles on an older roof are a warning sign: if the shingles crack when lifted to slide the flashing in, the roof may be due for replacement before solar. Our guide on timing a reroof with solar walks through that decision.

Standing-seam metal

This is the easy one. Clamps like S-5!'s S-5-RC grip the raised seam and are described by the manufacturer as a non-penetrating, zero-penetration attachment. No hole, no flashing. More on that in our post on solar on metal roofs.

Exposed-fastener and corrugated metal

Ag-style ribbed panels need brackets made for the profile, such as S-5!'s RibBracket and CorruBracket families. These do penetrate the panel, so the gasket and fastener choice matter. Pole barns and machine sheds fall in this group.

Tile, slate and flat roofs

Tile and slate use specialty hooks and replacement flashings. Low-slope membrane roofs on homes and businesses are a different system entirely, usually ballasted or flashed by the roofer. Ask who carries the roof warranty before anything is fastened.

Why Minnesota is hard on roof penetrations

Penetration leaks in Minnesota tend to show up in late winter, not July. Three Minnesota conditions explain why:

  • Ice dams. Water backs up under the lower shingle courses when snow melts over a warm attic and refreezes at the eave. A penetration in the bottom few feet of the roof sits right in that zone. Our ice dam guide covers layout choices that help.
  • Freeze-thaw cycling. Sealant that shrinks and expands through dozens of cycles a winter is the first thing to let go, which is why it shouldn't be the primary seal.
  • Wind-driven rain. Summer storms push water sideways and uphill under shingles. That's what the TAS 100(A) wind-driven rain test is designed to simulate.

Snow load matters too. The attachment carries the panel and the snow on it, so lag embedment and spacing come from the racking engineering, not from a rule of thumb.

8 questions to ask before an installer drills your roof

  1. Which attachment product will you use, and can I see its spec sheet and installation manual?
  2. Is it a flashed mount? If not, what is the primary water seal?
  3. Is the attachment part of a UL 2703-listed racking system?
  4. How do you find rafters, and what happens if a lag misses?
  5. Who fixes a leak at a penetration, for how long, and is that in writing?
  6. Will my roof manufacturer's warranty be affected?
  7. How do you handle nails that block the flashing?
  8. Are you also licensed to handle the roof itself if a shingle cracks during install?

Our solar bid checklist covers the rest of what belongs in writing, and do solar panels damage your roof? covers other leak sources like conduit penetrations. For a deeper look at the full racking stack, see solar panel mounting hardware.

Our solar flashing standard and warranty

On shingle roofs, iSolar uses flashed attachments installed to the manufacturer's manual by our in-house residential crews, and every install is backed by a SolarInsure 30-year warranty that includes roof penetrations. Because our sister company Three Rivers Contracting handles roofing, a cracked shingle gets fixed by people who do roofs. If you want to see how we'd lay out your roof, request a quote or read how we install.

Sources

Good questions

Frequently asked.

Do solar panels need flashing?

On asphalt shingle roofs, yes in our view. Flashing slides under the shingle course above each attachment so water sheds over the hole. Standing-seam metal roofs are the exception, because clamps grip the seam without penetrating the roof.

Is sealant enough to waterproof solar mounts?

Sealant alone is the weakest option because it's exposed to UV and freeze-thaw cycles. Most flashed products use sealant only in the pilot hole as a backup, with the shingle overlap and a gasket doing the main work.

Can solar panel mounts cause roof leaks?

They can if an attachment misses the rafter, the flashing isn't tucked far enough under the upper course, or the lag is over- or under-driven. Leaks are rare with flashed mounts installed to the manufacturer's manual.

Will installing solar void my roof warranty?

It depends on the shingle manufacturer and the roofer's workmanship warranty. Ask both your roofer and your solar installer in writing, and make sure the solar warranty covers roof penetrations.

What is the best solar mount for a metal roof?

For standing-seam metal, a seam clamp is usually best because it doesn't penetrate the roof panel. Corrugated or exposed-fastener metal roofs need brackets matched to the panel profile.

How long does solar flashing last?

Aluminum flashing and EPDM gaskets are designed to last the life of the array. Exposed sealant is the component most likely to need attention over time, which is why it shouldn't be the primary seal.