Knob and Tube Wiring in Minnesota Homes: What to Do About It
About four in ten homes in Minneapolis and St. Paul were built before 1940. Many still have some original knob and tube wiring, and it affects insurance, insulation and solar plans.

Reviewed by John Ihle, MN Master Electrician (AM005101) · NABCEP-credentialed · iSolar, Saint Paul Park, MN · Last reviewed October 2026
The short answer: Knob and tube wiring isn't automatically dangerous, but it has no ground, wasn't designed to be buried in insulation, and is often modified badly. Many insurers won't write or renew a policy until it's replaced or certified. Most Minnesota rewires keep the plaster by fishing new cable through walls; national cost guides put whole-house rewiring around $10,000 to $30,000.
Why so many Twin Cities homes still have knob and tube wiring
Knob and tube wiring was the standard way to wire North American homes from about 1880 into the 1940s. Two separate conductors, one hot and one neutral, ran through ceramic tubes in the framing and were held off the wood by ceramic knobs. There's no ground wire, and the cloth-and-rubber insulation was designed to shed heat into open air.
That era is exactly when much of the urban core was built. U.S. Census Bureau survey data (American Community Survey 2024, 1-year) shows the share of homes built in 1939 or earlier:
| Area | Housing units built 1939 or earlier | Built before 1950 |
|---|---|---|
| Minneapolis | 40.7% | 47.0% |
| St. Paul | 42.0% | 47.2% |
| Minnesota statewide | 15.3% | 19.3% |
Not every one of those homes still has active knob and tube. Many were rewired over the decades, often room by room. But on older homes in Minneapolis and St. Paul, our electricians regularly find at least a few live runs left, usually in upstairs bedrooms, ceiling lights and attic spaces.
How to tell if you have it
- Basement and attic: look for pairs of single wires spaced several inches apart, running through ceramic tubes or wrapped around ceramic knobs on joists.
- Two-prong outlets on the upper floors, especially if the basement has newer three-prong outlets.
- Old panel or fuse box feeding a few circuits that don't match the rest.
- Splices where newer cable is twisted onto old cloth-covered wire.
If an outlet tester shows "open ground" on a three-prong outlet upstairs, someone may have installed a grounded-style receptacle on ungrounded wire, which is worth flagging. Don't pull on wiring or open walls to check. Old insulation can crack when disturbed. A licensed electrician can survey it with the power off.
The real risks (not the scary-headline version)
Original knob and tube that's been left alone in open air can still be working. The problems come from age and from what people did to it later. InterNACHI, the home inspectors' association, lists the main concerns:
- No grounding conductor, so it can't safely serve three-prong appliances or electronics.
- Brittle insulation that cracks or flakes after a century of heat cycles.
- Amateur splices and extensions, which are easy to make because the wiring is so accessible.
- Not suitable for wet areas such as kitchens, bathrooms, laundry rooms and outdoors.
- Overfusing: a common field problem we see is a larger fuse or breaker swapped in to stop nuisance blowing, which removes the protection the old wire depends on.
The insulation rule that trips up energy upgrades
This is the Minnesota-specific headache. Knob and tube was built to cool itself in open air. The National Electrical Code (section 394.12) prohibits concealed knob and tube in hollow spaces of walls, ceilings and attics that are insulated with loose, rolled or foamed-in insulation that envelops the conductors. As one code commentary in EC&M puts it, once those spaces are insulated, existing concealed knob and tube can't stay in service.
So if you're planning blown-in attic insulation to fight ice dams and heating bills, live knob and tube in the attic floor has to be dealt with first. Energy auditors and insulation contractors will usually stop the job until it is. Our post on whether to insulate before going solar covers that sequence.
Knob and tube and your insurance
InterNACHI notes that many insurers refuse to cover homes with knob and tube because of fire risk, and some make exceptions when a licensed electrical contractor certifies the system. In practice, buyers often hear about it for the first time from the home inspector or the insurance agent during a purchase.
What insurers typically ask for:
- Whether any knob and tube is still energized, not just present.
- A letter or evaluation from a licensed electrician describing its condition and extent.
- A timeline to replace it, sometimes as a condition of binding.
- The permit and final inspection once rewiring is done.
Our post on homeowners insurance and solar covers the coverage conversation if you're adding panels too.
How rewiring is staged around plaster walls
The fear with old homes is that rewiring means tearing out plaster and lath. Usually it doesn't. A typical sequence:
- Survey and map. Identify every live knob and tube circuit and what it feeds.
- Panel first, if needed. Many of these homes still have 60- or 100-amp services. A new panel gives the new circuits somewhere to land and adds AFCI and GFCI protection.
- Attic and basement runs. Electricians use the open attic and basement as highways, dropping new cable down interior walls and fishing it up from below.
- Small, surgical openings. Where a run is blocked by fire blocking or a header, they cut small access holes, usually at baseboards or behind trim, instead of opening whole walls.
- Disconnect and abandon old wire. Old conductors are disconnected at both ends and left in the wall rather than pulled out.
- Inspection, then patching. The electrical inspector signs off before holes are patched.
If a full rewire has to wait, the NEC allows a two-prong outlet to be replaced with a GFCI receptacle labeled "No Equipment Ground," which adds shock protection but doesn't add a ground or fix aging wire. Treat it as a bridge, not a solution.
What rewiring costs
National cost guides from HomeGuide put whole-house rewiring around $10,000 to $30,000, or about $5 to $17 per square foot, with knob and tube replacement listed around $12,000 to $35,000. Twin Cities quotes vary a lot with house size, plaster, finished basements and whether the panel is replaced in the same job, so we price on site after a survey. Phasing by floor is common and keeps the house livable.
What moves the price on a Twin Cities rewire
- Access. An open, unfinished basement and a walkable attic make fishing wire far faster than a finished basement and a sealed half-story.
- Plaster and trim. Original woodwork you want preserved means more careful routing and smaller openings.
- Service size. Moving from a 60- or 100-amp service to 200 amps adds the panel, meter base and Xcel coordination.
- Scope creep you actually want. Kitchens and baths need new dedicated and GFCI-protected circuits anyway, so rewiring is the cheapest time to add them.
Solar, EV chargers and heat pumps on a knob and tube house
If you're planning electrification, the wiring question comes first. Solar ties into your panel, and an EV charger or heat pump adds big loads. Neither belongs on a 100-amp panel feeding century-old branch circuits. We usually scope it as one plan: service and panel, then rewiring, then the new loads. Our guide to an electrical panel upgrade for solar explains the service side, and our post on journeyman vs. master electricians covers who should be signing off on the work.
Get a knob and tube survey
iSolar's licensed electrical team surveys older homes, writes up what's live, and stages rewiring around plaster and your schedule. See our electrical services or request a quote; we'll call back the same business day.
Sources
- U.S. Census Bureau, ACS 2024 1-year, Table B25034 Year Structure Built (via Census Reporter)
- InterNACHI — Knob-and-Tube Wiring
- EC&M — Illustrated Code Catastrophes: Secs. 300.15, 410.23, 394.10, 394.12(5)
- EC&M — NEC Requirements When Replacing Nongrounding-type Receptacles (406.4(D)(2))
- HomeGuide — Cost to Rewire a House
Frequently asked.
Is knob and tube wiring illegal in Minnesota?
Existing knob and tube isn't automatically illegal, but new work can't use it and the NEC prohibits concealed knob and tube in spaces insulated with loose, rolled or foamed-in insulation. Any changes or extensions need a permit and must meet current code.
Will my insurance cover a house with knob and tube wiring?
Many insurers refuse to cover homes with active knob and tube, and some make exceptions if a licensed electrical contractor certifies its condition. Expect questions about whether it's energized and when it will be replaced.
How much does it cost to replace knob and tube wiring?
National guides from HomeGuide list knob and tube replacement around $12,000 to $35,000 and whole-house rewiring around $10,000 to $30,000. Minnesota pricing depends on house size, plaster, access and whether the panel is replaced too.
Can I put insulation over knob and tube wiring?
No, not while it's live. The NEC prohibits concealed knob and tube in hollow spaces insulated with loose, rolled or foamed-in insulation that surrounds the wires. Have it disconnected or replaced before insulating.
Do you have to open all the walls to rewire an old house?
Usually not. Electricians run new cable through the attic and basement and fish it through wall cavities, cutting small access holes only where needed. Old wire is disconnected and abandoned in place.
Can I add solar to a house with knob and tube wiring?
Solar connects at the panel, not on old branch circuits, but most knob and tube homes also have small, older services. Plan the panel and wiring updates first, then solar, so permits and inspections go smoothly.
Have a question we haven't covered?
Talk to a local iSolar expert — free, no pressure. Call (651) 565-1140.